Chat or Call
Damon Yao
Sales Manager - Damon Yao skypelive:damonyao_2
  • Phone
    Phone
    +86-13924617429
    Call me
  • WeChat
    Scan QR code and add WeChat
    +86-13924617429
    WeChat
  • WhatsApp
    Scan QR code and add WhatsApp
    +86-13924617429
    WhatsApp
  • E-mail
    E-mail
    yaoyihan@neware.com.cn
    Send Email
Mint Wu
Sales Manager - Mint Wu skypelive:.cid.d7553a84e2f43ba0
  • Phone
    Phone
    0013235717558
    Call me
  • WeChat
    Scan QR code and add WeChat
    17347019710
    WeChat
  • WhatsApp
    Scan QR code and add WhatsApp
    +86-13048860917
    WhatsApp
  • E-mail
    E-mail
    mint.wu@neware.com.cn
    Send Email
icon
Damon Yao
Sales Manager - Damon Yao skypelive:damonyao_2
  • Phone
    Phone
    +86-13924617429
    Call me
  • WeChat
    Scan QR code and add WeChat
    +86-13924617429
    WeChat
  • whatapp
    Scan QR code and add WhatsApp
    +86-13924617429
    WhatsApp
  • E-mail
    E-mail
    yaoyihan@neware.com.cn
    Send Email
Mint Wu
Sales Manager - Mint Wu skypelive:.cid.d7553a84e2f43ba0
  • Phone
    Phone
    0013235717558
    Call me
  • WeChat
    Scan QR code and add WeChat
    17347019710
    WeChat
  • whatapp
    Scan QR code and add WhatsApp
    +86-13048860917
    WhatsApp
  • E-mail
    E-mail
    mint.wu@neware.com.cn
    Send Email
Mint Wu
Sales Manager - Mint Wu skypelive:.cid.d7553a84e2f43ba0
  • Phone
    Phone
    0013235717558
    Call me
  • WeChat
    Scan QR code and add WeChat
    17347019710
    WeChat
  • WhatsApp
    Scan QR code and add WhatsApp
    +86-13048860917
    WhatsApp
  • E-mail
    E-mail
    mint.wu@neware.com.cn
    Send Email
icon
Select location or language
icon
MGDW Series
neware environmental chamber
The quality construction, long lasting durability and Future-Proof chamber performance are unmatched in the industry. Our test chambers help to achieve your environmental testing requirements. Whether your testing requires Temperature, Humidity, Thermal Shock, or other environments, we have you covered.
Every test chamber is customizable to fit your exact needs.
Neware Environmental Test Chambers incorporate innovative engineering and advanced technology. The quality construction, long lasting durability and Future-Proof chamber performance are unmatched in the industry.

Suitable is the best. High and Low Environmental Test Chambers .

MGDW Series - High and Low Temperature Chambers (Standard)

Volume: 150L/225L/408L/800L/1000L;
Test Method: GB/T 5170.2-2017;
Temperature Range: -40℃~150℃;
-40℃~+150℃;
-70℃~+150℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity);
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity);

More

MGDW Series - High and Low Temperature Chambers (Humidity)

Volume: 150L/225L/408L/800L/1000L;
Test Method: GB/T 5170.2-2017;
Temperature Range: -40℃~150℃;
-40℃~+150℃;
-70℃~+150℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity);
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity);

More

MGDW Series - High and Low Temperature Chambers (Flameproof)

Volume: 150L/225L/408L/800L/1000L;
Test Method: GB/T 5170.2-2017;
Temperature Range: -40℃~150℃;
-40℃~+150℃;
-70℃~+150℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity);
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity);
Functions: Explosion-proof pressure-relief port, Smog Testing and automatic (manual) smoke exhaust, etc.

More

MGDW Series - High and Low Temperature Chambers (Humidity & Flameproof)

Volume: 150L/225L/408L/800L/1000L;
Test Method: GB/T 5170.2-2017;
Temperature Range: -40℃~150℃;
-40℃~+150℃;
-70℃~+150℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity);
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity);
Functions: Explosion-proof pressure-relief port, Smog Testing and automatic (manual) smoke exhaust, etc.

More

MGDW Series - High and Low Temperature Chambers (Automatic Fire Extinguishing & Flameproof)

Volume: 150L/225L/408L/800L/1000L;
Test Method: GB/T 5170.2-2017;
Temperature Range: -40℃~150℃;
-40℃~+150℃;
-70℃~+150℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity);
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity);
Functions: Explosion-proof Pressure-relief Port, Smog Testing, Automatic (Manual) Smoke Exhaust and Carbon Dioxide (CO2) Automatic (Manual) Spray, etc.;

More

MGDW Series - High and Low Temperature Chambers (Automatic Fire Extinguishing, Flameproof & Humidity)

Volume: 150L/225L/408L/800L/1000L;
Test Method: GB/T 5170.2-2017;
Temperature Range: -40℃~150℃;
-40℃~+150℃;
-70℃~+150℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity);
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity);
Functions: Explosion-proof Pressure-relief Port, Smog Testing, Automatic (Manual) Smoke Exhaust and Carbon Dioxide (CO2) Automatic (Manual) Spray, etc.;

More

MGDW Series - High and Low Temperature Chambers (Double layer standard)

Volume: 150L/225L;
Test Method: GB/T 5170.2-2017;
Temperature Range: 20℃~150℃; -40℃~150℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity);
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity);

More

MGDW Series - High and Low Temperature Chambers (Double layer Flameproof)

Volume: 150L/225L;
Test Method: GB/T 5170.2-2017;
Temperature Range: -40℃~150℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity);
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity);
Functions: Explosion-proof pressure-relief port, Smog Testing and automatic (manual) smoke exhaust, etc.

More

MGDW Series - High and Low Temperature Chambers (Double layer Automatic Fire Extinguishing & Flameproof)

Volume: 150L/225L;
Test Method: GB/T 5170.2-2017;
Temperature Range: -40℃~150℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity);
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity);
Functions: Explosion-proof Pressure-relief Port, Smog Testing, Automatic (Manual) Smoke Exhaust and Carbon Dioxide (CO2) Automatic (Manual) Spray, etc.;

More

  • Neware Environmental Chamber
  • Neware Environmental Chamber
    Electronics/ Electrician /Instrument
  • Neware Environmental Chamber
    Material/ Semiconductor
  • Neware Environmental Chamber
    School/ Hospital/ Chemical Industry
  • Neware Environmental Chamber
    Environmental Protection
  • Neware Environmental Chamber
    Livestock/ Aquatic Products
neware environmental chamber
Every test chamber is customizable to fit your exact needs. Let our team help you find the very best approach.
NEWARE battery charge and discharge test system realizes integrated operation and collaborative work through BTS upper computer control system, so as to maximize the battery characteristics and functions.
Neware and Cookies
This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies.Read our private policy

Neware Official Website